image1 image2 image3

Workshops and Engine Test Beds, Horwich

 

During the development of this site the developer unearthed a number of underground storage tanks and associated contaminated soils and groundwater.
Due to lateral extent of the contamination plume, adjacent residential properties, the geological and hydro geological conditions in situ treatment was deemed to be the most practical method for the remediation of the site.
The underground storage tanks and localised contaminated materials were removed and a multiphase extraction system installed and operated. The building works continued throughout the nine month treatment period.

Client
Nationwide house builder
Site
Former workshops and racing engine test beds, Horwich, Lancashire
Problem
High octane fuel in soil and groundwater, underground storage tanks
Technologies utilised
Multi Phase vacuum extraction, vapour and liquid phase carbon absorption, excavation and off site disposal of contaminated soils, tank removal
Remediation criteria
VOC > 30ppm, Soil TPH <200mg/kg, Groundwater TPH < 5mg/l
Validation
Validated by independent consultant on completion

 